Is your steam or hot water wand dripping water or dispensing steam when closed? You came to the right place, and this is easily solved.
Below you will find instructions for replacing or cleaning the steam or hot water gasket in the Pro 700.
Tools Needed:
- Adjustable wrench
- Pick
1. Allow the machine to fully cool down.
2. Remove the fitting from the front of the steam or hot water valve using an adjustable wrench with a towel draped over the valve to protect it from being scratched.
3. Clean or replace the gasket inside the steam or hot water arm.