If your machine is not turning on you may find this troubleshooting guide to be helpful in figuring out what the cause is.
LUCCA light is the only thing that is on:
If this is the case, then the ribbon cable on the inside of the control panel has likely come unplugged. You can follow along with our panel removal article where it shows how to access the ribbon cable.
LUCCA + Boiler light only:
If these two lights are the only thing on, chances are your machine was filling the boiler for too long and timed out. Unplug your machine for 5 seconds, plug it back in and allow it to fill. If it happens multiple times, you may need to clean the fill solenoid. You can disable this alarm code by turning the steam boiler off (tap the boiler button), but you will not be able to steam or produce hot water from the tap.
No lights on at all:
Ensure the GFI outlet is not tripped, if machine is plugged into one. Check your fuse, located on the bottom of the machine. You may need to replace it.
Machine is tripping GFCI:
Check out our GFCI Troubleshooting guide: A53 Tripping GFCI Troubleshooting
Comments
1 comment
If this is the case, then the ribbon cable on the inside of the control panel has likely come unplugged. You can follow along with our panel removal article where it shows how to access the ribbon cable.
jasa service boiler
jual boiler winskettel
jual steam boiler 1.5 ton gas
distributor mesin steam boiler
distributor pipa boiler eropa
distributor boiler lokal
harga boiler di indonesia
jual boiler vertikal
jual burner riello R40
jual control burner simens
jual control burner honeywell
jual hot water boiler
jual pompa ksb lengkap
jual thermal oil murah
making steam boilers
thermal oil heater 400.000 kcal
Please sign in to leave a comment.