Below you will find instructions for cleaning the flow meter on the A53 Mini/Mini Vivaldi.
Tools needed:
- Phillips Screwdriver
- 3.5mm Allen Wrench
1. Remove the panels of the machine by following along with our guide: A53 Mini Panel Removal
2. Locate the flow meter, remove the 3 screws in the top of it. You may need to snip the zip tie holding the wires in place to more easily access the 3rd screw.
3. When the top of the flowmeter is removed, you'll see there is an inlet and outlet pointed out here, make sure both passageways are clear and that the white magnet sensor spins freely.
Comments
0 comments